166
Three Phase ODP Motors
Features:
• Ball Bearings
• Class B or F Insulation
(as noted)
• Continuous Duty
• Energy Efficient
$
• Dripproof
• NEMA Design B
• Rigid Base
Applications:
Pumps, fans, compressors, conveyors
.
Full Load
Stock
Insul.
Cast
“C”
HP RPM
Volts
Amps
Frame
Number
Protector Class Iron Type
Dim.
Efficiency Notes
3
3600 200-230/460 8.4-7.4/3.7
145T
E1013
J
None
B
E+
14.3
84.0
460/200-230 4.3/9.0-8.6
56HZ
H757
Auto
B
13.8
15,35
1800
200
9.8
182T
E202M
J
None
F
E+
13.7
86.5
200
8.9
182T
E216V1
J
None
F
E+3(NP)
13.7
89.5
200-208
10.0-9.7
56HZ
H518
None
B
14.6
15
230/460
8.6/4.3
182T
E226M
J
None
F
E+
13.7
86.5
230/460
8.6/4.3
182T
E217V1
J
None
F
E+3(NP)
13.7
89.5
460/200-230 4.4/9.0-8.8
56HZ
H887
Auto
B
14.6
15,35
460/230
4.4/8.8
56HZ
H539
None
B
14.6
15
575
3.6
56HZ
H955
Auto
B
14.6
15
575
3.4
182T
E923
J
None
F
E+3(NP)
13.7
89.5
575
3.4
182T
E224
J
None
F
E+
13.7
86.5
1200 200-230/460 10.5-10.0/5.0
213T
E314
J
None
F
E+
17.5
86.5
230/460
9.3/4.65
213T
E394
J
None
F
E+3(NP)
16.6
89.0
5
3600 200-230/460 13.2-12.4/6.2
182T
E208
J
None
F
E+
14.7
85.5
230/460
11.6/5.8
182T
E204
J
None
F
E+3(NP)
14.6
91.0
460/208-230 6.6/13.4-13.2
56HZ
H847
Auto
B
15.1
15
575
5.4
56HZ
H956
Auto
B
15.1
15
1800
200
14.8
184T
E203M
J
None
F
E+
13.7
87.5
200
15.7
184T
E218
J
None
F
E+3(NP)
13.7
89.5
200-208
16.0/16.0
184T
R213M
None
B
12.6
84.0
200-208
16.0-16.0
184T
R239
Auto
B
14.1
84.0
1
230/460
12.8/6.4
184T
E227M
J
None
F
E+
13.7
87.5
200-230/460 15.3-12.8/6.4
184T
E2001
Auto
F
E+
13.7
87.5
230/460
13.6/6.8
184T
E219
J
None
F
E+3(NP)
13.7
89.5
575
5.4
184T
E924
J
None
F
E+3(NP)
13.7
89.5
575
5.1
184T
E225
J
None
F
E+
13.7
87.5
1200 200-230/460 16.7-15.6/7.8
215T
E315
J
None
F
E+
17.5
87.5
230/460
15.2/7.6
215T
E395
J
None
F
E+3(NP)
17.6
89.5
Notes:
Continues on next page
 1. To be discontinued when stock is depleted
15. 56 HZ = 7/8” x 2-5/16” shaft
35. Quick Connect design bracket
Published efficiency on tri-voltage rated motors applies at 230/460 volts.
Performance at 200 or 208 volts may not be in accordance with NEMA standards.
Published efficiency on 200-208 volt motors applies at 200 volts.
• Squirrel Cage
• Standard, EPAct CC001A
(E-Plus
®
motors) and Premium
(E-Plus
®
3 motors) Efficiency
• 1⁄4 thru 400 HP
• 1.15 Service Factor
• 40°C Ambient
• 60 Hz
• 3600, 1800 and 1200 RPM
• E-Plus
®
Motors meet the require-
ments of the Energy Policy Act of
1992. E-Plus
®
3 motors exceed the
requirements of the Energy Policy
Act of 1992.
E+3(NP) is NEMA
Premium Efficient.
Continued from previous page
E1013
Motors specially designed, tested and warranted to
be
Corona-Free
for compatible inverter duty are
marked on this page with a
J
. See page 4 and 5
of this catalog for more Speed Engineered
®
motors
information.
1...,158,159,160,161,162,163,164,165,166,167 169,170,171,172,173,174,175,176,177,178,...324